Nevada Electrical (C2) Contractor License

The Electrical (C2) Contractor License allows you to install, change and preserve systems that are wind energy based for residential and commercial with non-profit purposes. You will also be able to do the following work:

  • Electrical wires
  • Fixtures
  • Appliances
  • Apparatuses
  • Raceways
  • Conduits

The Electrical (C2) Contractor License allows you to perform the work of any of the subclassifications:

  • Electrical Wiring (C2A):
    • Electrical wires
    • Fixtures
    • Appliances
    • Apparatuses
  • Integrated Ceilings (C2B):
    • The installation, alteration and repair of:
      • Wiring
      • Fixtures
      • Suspensive systems
      • Ducts and other related apparatuses of integrated ceilings
      • Interior electrical illumination
      • Modular units, each unit containing an electrical lighting fixture
      • Incidental acoustical tile or a similar material
  • Fire Detection (C2C):
    • Electrical sensors
    • Alarms
    • All appurtenances and related wiring
  • Low Voltage (C2D):
    • Installation, alteration, and repair of systems that:
      • Use fiber optics
      • Do not exceed 91 volts
    • Including the following systems:
      • Telephone
      • Sound
      • Cable television
      • Closed circuit video
      • Satellite dish antennas
      • Instrumentation controls
      • Temperature controls
      • Computer networking
      • Landscape lighting

How to Get the Electrical (C2) Contractor’s License in Nevada?

  1. Attain a Nevada business ID before starting the NV Contractor Application. To obtain the Nevada business ID, an application for a Nevada Business License must be submitted to the Nevada Secretary of State
  2. Accumulate the necessary documents requested by the Nevada State Contractors Board (NSCB) and submit them with your contractor application
  3. Present proof of past work history by submitting one of the following types of documentation:
    • FourCertification of Work Experience Forms (Certificates)
      • Each certification of experience time must equal a minimum of 4 full years (1460 days)
    • Proof of eligibility forLicensure by Endorsement. Applicants are advised to review theState Equivalency Chart to determine their eligibility. To be considered for licensure by endorsement, you must submit aRequest for Verification of License with your application, completed by your endorsing state
    • Proof of transferrable military training and experience
    • An active Master's Certification issued by an officially recognized agent or governmental agency similar to the Electrical (C2) classification
  4. Complete and send the Nevada Contractor License Application form with all completed forms
  5. Wait for an Examination Eligibility Form from the NSCB once the application has been sent and the Electrical (C2) work experience has been confirmed
  6. Take and pass the Management Survey Business and Law Exam (CMS) and Electrical (C2) trade exam administered by PSI©
  7. With the approval of the license by the NV State Contractors Board, the applicant must send proof of Workers' Compensation Insurance and thelicense bond indicated on the approval letter
  8. Expect for the Electrical (C2) contractor license by mail once the NSCB issues the license

Nevada Electrical (C2) Contractor License Exam Prep Courses

Nevada Electrical (C2) Contractor License Exams

Below is all the information related to the trade and Management Survey exams, including the official reference lists.

Nevada Electrical (C2) Contractor Trade Exam

  • Testing Method: Computer Based
  • Testing Company: PSI©
  • Number of Questions: 80
  • Types of Questions: Multiple Choice
  • Time Allowed: 4 Hours
  • Minimum Passing Score: 56 Questions
  • Subjects Involved (No. of Questions):
    • General Electrical Knowledge (6)
    • Service, Feeders, and Branch Circuits (7)
    • Grounding and Bonding (7)
    • Conductors and Cables (8)
    • Raceways and Boxes (7)
    • Special Occupancies and Equipment (5)
    • Electrical Power (6)
    • Motors (6)
    • Low Voltage (2)
    • Lighting (5)
    • Illuminated Signs (2)
    • Fire Detection and Alarm Systems (2)
    • Safety Information (8)
    • Transmission Lines (5)
    • Overcurrent Protection (4)
  • PSI© Electrical (C2) Official Content Outline

Nevada Electrical (C2) Contractor Management Survey Exam

  • Testing Method: Computer Based
  • Testing Company: PSI©
  • Types of Questions: Multiple Choice
  • Number of Questions: 60
  • Time Allowed: 120 Minutes
  • Minimum Passing Score: 45 (75% correct)
  • Subjects Involved (No. of Questions):
    • Licensing (10)
    • Estimating and Bidding (7)
    • Lien Law (3)
    • Financial Management (12)
    • Tax Laws (5)
    • Labor Laws (5)
    • Project Management (3)
    • Contracts (6)
    • Risk Management (4)
    • Environmental and Safety (5)
  • PSI© Management Survey Official Content Outline

Nevada Electrical (C2) Contractor Book Set

This set of books includes all required references for the Electrical (C2) and Management Survey exams. Orders placed before 2 PM are shipped the same day via UPS and a tracking number is emailed before 3 PM.

  • NEVADA ELECTRICAL (C2) - BOOK SET WITHOUT TABS INCLUDES ALL BOOKS FOR TRADE AND BUSINESS EXAMS

    Sales price: $914.56
  • NEVADA ELECTRICAL (C2) - BOOK SET WITH TABS INCLUDES ALL BOOKS FOR TRADE AND BUSINESS EXAMS

    Sales price: $984.56

Nevada Electrical (C2) Contractor Exam Books

Books Allowed in Testing

Books Not Allowed in Testing

Nevada Electrical (C2) Management Survey Exam Book

Book Allowed in Testing