Oregon Underground Storage Tank Service Supervisor License

The Underground Storage Tank Service Supervisor License allows you to do the following work:

  • Supervise underground storage tank services, such as:
    • Installation
    • Decommissioning
    • Modification
    • Testing for cathodic protection and tank tightness
    • Inspection

How to Get the Underground Storage Tank Service Supervisor’s License in Oregon?

  1. Take and pass the applicable trade exam(s) for the Oregon Underground Storage Tank Service Supervisor license given by the International Code Council (ICC©):
  2. Send the application form within 30 days of passing the qualifying exam(s) to the given address, including the following:
    • Required application fee
    • Full name and address of the candidate
    • Name, address, and e-mail address of the Service Provider that the individual is employed by or regularly associated with
    • Original or legible copy of documentation that the applicant has successfully passed the needed supervisor examination(s)
  3. Receive a certification card valid for twenty-four months issued by the UST Department once the application is validated

Oregon Underground Storage Tank Service Supervisor License Exam Prep Course

Oregon Underground Storage Tank Service Supervisor License Exams

Below is all the information related to the trade exams, including the official reference lists.

UST Installation/Retrofitting Trade Exam

  • Testing Method: Computer-based
  • Testing Company: ICC©
  • Number of Questions: 70
  • Types of Questions: Multiple choice
  • Time Allowed: 90 Minutes
  • Minimum Passing Score: 49 Questions (70%)
  • Subjects Involved (No. of Questions):
    • Site Preparation (12)
      • Property Clearances (1)
      • Site Drainage (1)
      • UST System Layout (3)
      • Tank Unloading (1)
      • Pre-Installation Testing (6)
    • Materials (5)
      • Verify Materials (1)
      • Tank Condition and Protective Coating (1)
      • Valves, Fittings & Materials (2)
      • Compatibility (1)
    • Excavation, Bedding, and Backfill (13)
      • UST System Excavation (3)
      • Burial Depth (4)
      • Tank and Pipe Bedding (3)
      • Backfill Tanks (2)
      • Tank Deflection (1)
    • Placement of Equipment (13)
      • Tank Anchoring (3)
      • Ballast Tanks (1)
      • Tank Fill Lines, Devices and Connections (2)
      • Product Pipe Installation (2)
      • Vent Piping (2)
      • Automatic Leak Detection Systems (1)
      • Observation Wells and Ground Water Wells (2)
    • Secondary Containment (5)
      • Tank Overfill Protection (2)
      • Tank and Pipe Secondary Containment (3)
    • Vapor Recovery Systems (2)
      • Stage I Vapor Recovery (1)
      • Stage II Vapor Recovery (1)
    • Tank Decommissioning and Cleaning (2)
      • System Draining and Waste Liquid Disposal (1)
      • Tank Purging (1)
    • Cathodic Protection (5)
      • Tank and Pipe Coating (1)
      • Galvanic Anode (1)
      • System Electrical Isolation (3)
    • Test Methods and Testing Requirements (4)
      • Release Detection Requirements (3)
      • Periodic Tests at Required Intervals (1)
    • Health and Safety for UST Workers (9)
      • Control of Vapors and Sources of Ignition (4)
      • Excavation Safety (2)
      • Grounding and Bonding of Equipment (1)
      • Personal Safety Equipment (1)
      • Health Safety Regulations (1)
  • ICC© UST Installation/Retrofitting Official Content Outline

UST Tank Tightness Testing Trade Exam

  • Testing Method: Computer-based
  • Testing Company: ICC©
  • Number of Questions: 50
  • Types of Questions: Multiple choice
  • Time Allowed: 60 Minutes
  • Minimum Passing Score: 35 Questions (70%)
  • Subjects Involved (No. of Questions):
    • Records and Reporting Requirements (4)
      • Line and Tank Tightness Test Records (2)
      • Reporting of Failed Results and Releases (2)
    • Site Preparation and Layout (3)
      • UST System Layout (3)
    • Placement of Equipment (2)
      • Tank Fill Lines, Devices, Connections, and Tank Caps (1)
      • Automatic Leak Detection Systems (1)
    • Secondary Containment (2)
      • Tank and Overfill Protection (1)
      • Tank and Pipe Secondary Containment (1)
    • Vapor Recovery Systems (1)
      • Stage I and Stage II Vapor Recovery Systems (1)
    • Test Variables and Leak Detection Requirements (12)
      • Release Detection Requirements (3)
      • Test Methods (3)
      • Periodic Tests at Required Intervals (1)
      • Water Table (2)
      • Interpretation of Test Results (3)
    • Volumetric Tightness Testing (8)
      • Preparation for Tank Tightness Testing (4)
      • Conducting Volumetric Tank Tightness Tests (4)
    • Nonvolumetric Tightness Testing (4)
      • Nonvolumetric Tightness Testing (4)
    • Health and Safety for UST Workers (6)
      • Control of Vapors and Sources of Ignition (4)
      • Grounding and Bonding of Equipment (1)
      • Personal Safety Equipment (1)
    • Testing of Piping Systems (8)
      • Preparation for Pipe Tightness Testing (4)
      • Conduct Line Tightness Tests (3)
      • Compare Data to Threshold Values (1)
  • ICC© UST Tank Tightness Testing Official Content Outline

UST Decommissioning Trade Exam

  • Testing Method: Computer-based
  • Testing Company: ICC©
  • Number of Questions: 60
  • Types of Questions: Multiple choice
  • Time Allowed: 90 Minutes
  • Minimum Passing Score: 42 Questions (70%)
  • Subjects Involved (No. of Questions):
    • Reporting Requirements (8)
      • Reporting of Releases (4)
      • System Closure Records (4)
    • Site Preparation and Layout (4)
      • Property Clearances (1)
      • Site Soils Observation (1)
      • Site Drainage (2)
    • Tank Decommissioning and Cleaning (24)
      • System Draining (3)
      • Waste Liquid Disposal (2)
      • Tank Purging (9)
      • Tank Inerting (4)
      • Remove Tank and Tank Fixtures (2)
      • Tank Cleaning, Recycling and/or Reuse (2)
      • In-Place Tank Closure (2)
    • Storage and Transportation of Tanks (5)
      • Temporary Tank Storage (3)
      • Cap Tank Openings (2)
    • Health and Safety for UST Workers (19)
      • Control of Vapors and Sources of Ignition (9)
      • Excavation Safety (3)
      • Grounding and Bonding of Equipment (1)
      • Personal Safety Equipment (4)
      • Health Safety Regulations (2)
  • ICC© UST Decommissioning Official Content Outline

UST Cathodic Protection Trade Exam

  • Testing Method: Computer-based
  • Testing Company: ICC©
  • Number of Questions: 50
  • Types of Questions: Multiple choice
  • Time Allowed: 60 Minutes
  • Minimum Passing Score: 35 Questions (70%)
  • Subjects Involved (No. of Questions):
    • Records and Reporting (3)
      • Reporting of Releases (1)
      • System Records (2)
    • Site Data, Layout, and Pretest (8)
      • Site Soils Observation (6)
      • UST System Layout (2)
    • Basic Design, Identification, and Inspection (11)
      • Measure Potential and Test Continuity (5)
      • Identify and Determine Cathodic Protection System (5)
      • Tank and Pipe Anode Quantity, Material Size and Location (1)
    • Galvanic Anode Cathodic Protection (12)
      • Tank and Pipe Coating (3)
      • Galvanic Anode (3)
      • System Electrical Isolation (2)
      • Monitor, Inspect, and Maintain Galvanic Protection Systems (1)
      • Design Galvanic Corrosion Protection Systems (3)
    • Impressed Current Cathodic Protection (11)
      • Impressed Current Rectifier (2)
      • Impressed Current Anode (3)
      • Design Impressed Current Systems (3)
      • Monitor / Inspect / Maintain Impressed Systems (3)
    • Health and Safety for UST Workers (5)
      • Control of Vapors and Sources of Ignition (2)
      • Grounding and Bonding of Equipment (1)
      • Personal Safety Equipment (2)
  • ICC© UST Cathodic Protection Official Content Outline

Oregon Underground Storage Tank Service Supervisor Book Set

This set of books includes all required references for the Underground Storage Tank Service Supervisor exam. Orders placed before 2 PM are shipped the same day via UPS and a tracking number is emailed before 3 PM.

  • OREGON UNDERGROUND STORAGE TANK SERVICE SUPERVISOR - BOOK SET WITHOUT TABS INCLUDES ALL BOOKS FOR TRADE AND BUSINESS EXAMS

    Sales price: $2,057.85
  • OREGON UNDERGROUND STORAGE TANK SERVICE SUPERVISOR - BOOK SET WITH TABS INCLUDES ALL BOOKS FOR TRADE AND BUSINESS EXAMS

    Sales price: $2,157.85

Oregon UST Installation/Retrofitting (U1) Exam Books

Books Not Allowed in Testing

Oregon UST Decommissioning (U2) Exam Books

Books Not Allowed in Testing

Oregon UST Tank Tightness Testing (U3) Exam Books

Books Not Allowed in Testing

Oregon UST Cathodic Protection (U4) Exam Books

Books Not Allowed in Testing

The following books apply for more than one of the Underground Storage Tank Service Supervisor examinations:

  • Recommended Practices for Installation of Underground Liquid Storage Systems RP100
    • UST Installation/Retrofitting (U1)
    • UST Decommissioning (U2)
    • UST Tank Tightness Testing (U3)
    • UST Cathodic Protection (U4)
  • Recommended Practices for Installation and Testing of Vapor Recovery Systems at Vehicle Fueling Sites RP300
    • UST Installation/Retrofitting (U1)
    • UST Tank Tightness Testing (U3)
  • Technical Standards and Corrective Action Requirements for Owners and Operators of USTs EPA 40 C.F.R. PART 280.10-280.74
    • UST Installation/Retrofitting (U1)
    • UST Tank Tightness Testing (U3)
    • UST Cathodic Protection (U4)
  • Health and Safety Training for Underground Storage Tank Inspectors, Students Guide EPA 910/B-92/001
    • UST Installation/Retrofitting (U1)
    • UST Decommissioning (U2)
    • UST Tank Tightness Testing (U3)
    • UST Cathodic Protection (U4)