Nevada Fire Protection (C41) Contractor License
The Fire Protection (C41) Contractor License allows you to perform the work of any of the following authorized classifications:
Automatic fire sprinklers (C41A)
- Wiring
- Excavation
- Backfilling
- Grading
- Piping to a water supply
- Fabrication, installation, alteration, repair and service of water powered fire protection systems such as:
- Pressure and storage tanks
- Fire pumps and drivers
- Sprinkler heads and nozzles
- All associated valves and piping
Fixed fire extinguishing systems (C41B)
- Fabrication, installation, repair and service of foam, gas or dry chemicals fire protection systems like:
- Pressurized storage tanks
- Valves
- Associated piping
- Sensing and control devices
- Fabrication, installation, repair and service of foam, gas or dry chemicals fire protection systems like:
Fire alarms (C41C)
- The installation, alteration, repair and servicing of:
- Electrical sensors
- Alarms used to detect heat and smoke
- Wiring
- All related appurtenances
- The installation, alteration, repair and servicing of:
Private fire hydrants (C41D)
- The existing privately owned fire hydrants:
- Inspection
- Testing
- Maintenance
- Repair
- Parts replacement
- The existing privately owned fire hydrants:
How to Get the Fire Protection (C41) Contractor’s License in Nevada?
- Attain a Nevada business ID before starting the NV Contractor Application. To obtain the Nevada business ID, an application for a Nevada Business License must be submitted to the Nevada Secretary of State
- Accumulate the necessary documents requested by the Nevada State Contractors Board (NSCB) and submit them with your contractor application
- History of past and current employment
- Select the Fire Protection (C41) contractor license from the official list of Nevada State Contractors
- Provide a Signature on the application where requested
- Experience Documentation
- Copies of driver's licenses or government-issued IDs
- Submit a check, cashier's check, or money order payable to NSCB
- Child Support Information Statement – Sole Proprietors ONLY
- Background Disclosure Statement andFingerprint Background Waiver forms
- Financial Statement
- Present proof of past work history by submitting one of the following types of documentation:
- FourCertification of Work Experience Forms (Certificates)
- Each certification of experience time must equal a minimum of 4 full years (1460 days)
- Proof of eligibility forLicensure by Endorsement. Applicants are advised to review theState Equivalency Chart to determine their eligibility. To be considered for licensure by endorsement, you must submit aRequest for Verification of License with your application, completed by your endorsing state
- Proof of transferrable military training and experience
- An active Master's Certification issued by an officially recognized agent or governmental agency similar to the Fire Protection (C41) classification
- FourCertification of Work Experience Forms (Certificates)
- Complete and send the Nevada Contractor License Application form with all completed forms
- Wait for an Examination Eligibility Form from the NSCB once the application has been sent and the Fire Protection (C41) work experience has been confirmed
- Take and pass the Management Survey Business and Law Exam (CMS) and Fire Protection (C41) trade exam administered by PSI©
- With the approval of the license by the NV State Contractors Board, the applicant must send proof of Workers' Compensation Insurance and thelicense bond indicated on the approval letter
- Expect for the Fire Protection (C41) contractor license by mail once the (NSCB) issues the license
Nevada Fire Protection (C41) Contractor License Exam Prep Courses
Nevada Fire Protection (C41) Contractor License Exams
Below is all the information related to the trade and Management Survey exams, including the official reference lists.
Nevada Fire Protection (C41) Contractor Trade Exam
- Testing Method: Computer Based
- Testing Company: PSI©
- Number of Questions: 90
- Types of Questions: Multiple Choice
- Time Allowed: 3 Hours
- Minimum Passing Score: 63 Questions
- Subjects Involved (No. of Questions):
- Fire Sprinkler Systems (20)
- Fire Sprinkler - Wet and Dry Chemical Systems (17)
- Fire Sprinkler – Standpipe (10)
- Fire Prevention – Inspections, Testing, and Maintenance (7)
- Code Compliance (3)
- Fire Alarms (23)
- General Regulations (10)
- PSI© Fire Protection (C41) Official Content Outline
Nevada Fire Protection (C41) Contractor Management Survey Exam
- Testing Method: Computer Based
- Testing Company: PSI©
- Types of Questions: Multiple Choice
- Number of Questions: 60
- Time Allowed: 120 Minutes
- Minimum Passing Score: 45 (75% correct)
- Subjects Involved (No. of Questions):
- Licensing (10)
- Estimating and Bidding (7)
- Lien Law (3)
- Financial Management (12)
- Tax Laws (5)
- Labor Laws (5)
- Project Management (3)
- Contracts (6)
- Risk Management (4)
- Environmental and Safety (5)
- PSI© Management Survey Official Content Outline
Nevada Fire Protection (C41) Contractor Book Set
This set of books includes all required references for the Fire Protection (C41) and Management Survey exams. Orders placed before 2 PM are shipped the same day via UPS and a tracking number is emailed before 3 PM.
NEVADA FIRE PROTECTION (C41) - BOOK SET WITHOUT TABS INCLUDES ALL BOOKS FOR TRADE AND BUSINESS EXAMS
Sales price: $1,201.13-
NEVADA FIRE PROTECTION (C41) - BOOK SET WITH TABS INCLUDES ALL BOOKS FOR TRADE AND BUSINESS EXAMS
Sales price: $1,301.13
Nevada Fire Protection (C41) Contractor Exam Books
Books Allowed in Testing
-
NFPA 13 Standard for Installation of Sprinkle...NFPA 13 Standard for Installation of Sprinkle
r1412 1$170.16$170.16 -
The 2007 edition of NFPA 14, Standard for the...NFPA 14 Standard for the Installation of Stan
r1264 1$85.36$85.36 -
This book covers criteria that cover total fl...NFPA 17 Standard for Dry Chemical Extinguishi
r1422 1$77.45$77.45 -
The National Fire Alarm and Signaling Code, N...NFPA 72 National Fire Alarm and Signaling Cod
r1292 1$158.78$158.78 -
NFPA 11 Standard for Low-Expansion Foam is th...NFPA 11 Standard for Low-Expansion Foam 2016
r1423 1$174.94$174.94 -
NFPA 12 Standard on Carbon Dioxide Extinguish...NFPA 12 Standard on Carbon Dioxide Extinguish
r1424 1$85.98$85.98 -
The 2008 edition of NFPA 25 presents guidelin...NFPA 25 Standard for Inspection Testing & Mai
r1414 1$130.00$130.00 -
The National Fire Protection Association (NFP...NFPA 70 National Electrical Code 2011
r1285 1$166.34$166.34
Book Not Allowed in Testing
-
The Nevada Fire Marshal Code, Chapter 477, pr...Nevada Fire Marshall Code Chapter 477
r1415 1$55.01$55.01
Nevada Fire Protection (C41) Management Survey Exam Book
Book Allowed in Testing
-
Nevada Construction Business and Law Manual i...Nevada Construction Business and Law Manual
r1418 1$97.11$97.11